3-axis Measurement |
|
3D Orientation |
|
Hard-Iron Correction |
|
Integrated Processor |
|
Module |
TCM 2.5
Note: This product is designed as a replacement/upgrade module for the TCM2-20 and TCM2-50 in existing applications. New applications should be designed using the TCM 2.6 instead of the TCM 2.5.
The TCM 2.5 is a 3-axis tilt-compensated compass-heading (also known as azimuth, yaw, or bearing angle) module with electronic gimballing to provide accurate heading, pitch, and roll measurements over a ±50° tilt range.
With built-in hard-iron correction, low power demands, and digital output, the TCM 2.5 is a cost-effective, reliable solution to measure compass heading, tilt, and calibrated or uncalibrated magnetic field intensity in three dimensions.
- Backward-Compatible Footprint
6.4 × 5.1 × 1.4 cm
- Digital Interface
RS-232 Compatible
NMEA0183
- Hard-Iron Calibration
Built-in algorithms correct compass heading near magnetic sources and materials
- High Precision
Heading accuracy 0.8°
- High Resolution
Compass heading 0.1°
- High Resolution Field Measurement
0.05 µT (0.0005 Gauss)
- Low Power
< 20 mA typical draw
- Wide Field Measurement Range
± 80 µT (± 0.8 Gauss)
- Wide Temperature Range
−20 to 70 °C (operational)
- Full Tilt Compensation
± 50°
- RoHS Compliant
Heading Specifications
| Accuracy (RMS) |
0.8° |
| Max Dip Angle |
85° |
| Repeatability (RMS)1 |
0.1° |
| Resolution |
0.1° |
Magnetometer Specifications
| Calibrated Field Measurement Range |
± 80 µT |
| Magnetic Repeatability |
± 0.1 µT |
| Magnetic Resolution |
± 0.05 μT |
Tilt Specifications
| Pitch Accuracy |
0.2° RMS |
| Roll Accuracy (RMS) |
0.2° |
| Tilt Range |
± 50° |
| Tilt Repeatability2 |
0.1° |
| Tilt Resolution |
0.1° |
Calibration
| Hard Iron Calibration |
Yes |
| Soft Iron Calibration |
No |
Mechanical Specifications
| Connector for RS-232 Interface |
10-Pin |
| Dimensions (L × W × H) |
6.4 × 5.1 × 1.4 cm |
| Mounting Options |
Screw Mount / Standoffs Horizontal |
| Weight |
20 grams |
I/O Specifications
| Communication Rate |
300 to 115200 baud |
| Latency from Power-On |
< 50 ms |
| Latency from Sleep Mode |
< 1 ms |
| Maximum Sample Rate |
8 samples/sec |
| Output Formats |
TCM2 Protocol NMEA0183 |
Power Specifications
| Idle Mode |
18 mA |
| Sleep Mode |
0.6 mA |
| Supply Voltage (VDC) |
5 V (Regulated) 6 to 18 V (Unregulated) |
Typical Current Draw (Continuous Output) |
Maximum: 22 mA Typical: < 20 mA |
Environmental Specifications
| Humidity |
Non-condensing / Qualified to MIL-STD-810F |
| Operating Temperature Range |
−20 to 70 °C |
| Shock |
2500 g, per MIL-STD-810F |
| Storage Temperature Range |
−40 to 85 °C |
| Vibration |
Qualified to MIL-STD-810F |
| 1 |
Repeatability is based on statistical data at ± 3 sigma limit about the mean |
| 2 |
Repeatability is based on statistical data at ± 3 sigma limit about the mean |